Thomas Zampatori Jr

post-incident analysis created by GFD Officers

Incident Number
21-2156
Date
June 18, 2021
Time
22:34
Address
2317 Lyell Ave - Taco Bell
Rochester, NY 14606

Description

DISPATCHED FOR THE AUTOMATIC ALARM AT THE RESTAURANT.  ARRIVED TO FIND SMOKE IN THE BUILDING, 4522 REQUESTED THE BALANCE OF THE ASSIGNMENT.  SUBSEQUENT ARRIVING UNITS REPORT FIRE VISIBLE FROM A LIGHT FIXTURE  AT THE FRONT OF THE BUILDING, COMMAND IS ESTABLISHED.  4522 IS ABLE TO SECURE POWER INSIDE THE BUILDING WHICH APPEARS TO HELP REDUCE THE AMOUNT OF FIRE VISIBLE.

 

22:52 Hours -- UPDATE FROM COMMAND THAT THE INCIDENT IS A PRIMARILY EXTERIOR FIRE AT AN APPROXIMATELY 50' x 100'' WOOD FRAME BUILDING, ONE HAND LINE IS STRETCHED & ALL HANDS ARE WORKING.  ALSO CONFIRMING THAT THE PRIMARY SEARCH OF THE BUILDING HAS BEEN COMPLETE WITH NEGATIVE RESULTS.  

 

22:55 Hours -- FILL-IN COMPANIES ARE REQUESTED; ST 1-4310, ST 2-E3, ST 3-2912.

 

23:03 Hours -- COMMAND REPORTS THAT THE FIRE APPEARS TO BE KNOCKED DOWN & COMPANIES ARE SEARCHING FOR EXTENSION - NO NEED FOR 20 MINUTE MARKS.  

 

23:08 Hours -- 4512 REPORTS FIRE ABOVE THE CEILING ON THE 'B' SIDE OF THE BUILDING.  4C15 ASSUMES COMMAND, 4C35 ASSIGNED TO OPERATIONS, AN ADDITIONAL COMPANY IS REQUESTED TO THE SCENE AS THE RIC & A WORKING FIRE IS DECLARED.  

 

23:14 Hours -- E3 IS ASSIGNED AS THE RIC UPON ARRIVAL TO THE SCENE.  AN ENGINE FROM RIDGE ROAD FD WAS REQUESTED TO FILL IN AT ST 2 WHEN E3 WAS REQUESTED TO THE SCENE, 252 RESPONDS.  

 

23:19 Hours -- OPERATIONS REPORTS THAT COMPANIES IN THE KITCHEN HAVE FIRE ABOVE THE CEILING, A SECOND ALARM FIRE IS DECLARED., 4310, 252 & 2912 RESPOND AS WELL AS 2C39. 4C85 IS ASSIGNED TO SAFETY  252 & 2912 ARE TO STAGE NEAR THE SCENE, 4310 TO CONTACT OPERATIONS ON ARRIVAL.

 

23:23 Hours -- 252 TO ENTER THE WEGMANS PARKING LOT FROM LYELL AVE.

 

23:24 Hours -- A SECOND DISPATCHER IS REQUESTED, DISP EMERSON RESPONDING

 

23:27 Hours -- 2912 STAGED ON HOWARD RD, 4310 ON SCENE.  20 MINUTE MARKS BEGUN

 

23:30 Hours -- FILL-IN'S ENROUTE; ST 1-270, ST 2-223, ST 3-423.  BC COOPER RETURNING AS THE DUTY OFFICER

 

23:32 Hours -- ADVISED COMMAND THAT TOTAL TIME FOR INCIDENT IS 55 MINUTES & A DRIVER IS AT HQ FOR 4518.  4518 TO THE SCENE NON-EMERGENT.

 

23:36 Hours -- UPDATE THAT GATES AMBULANCE HAS ESTABLISHED REHAB, 4C15 REQUESTING THE FIRE MARSHAL OR TOWN BUILDING REP TO CONTACT HIM OR RESPOND.

 

23:44 Hours -- COMMAND REQUESTING A HEALTH DEPARTMENT REP TO CONTACT HIS CELL PHONE

 

23:46 Hours -- OPERATIONS REPORTING NO ACTIVE FIRE NOTED & NO HEAT SIGNATURES ON THERMAL IMAGING CAMERAS.

23:47 Hours -- COMMAND DECLARES FIRE UNDER CONTROL, FINAL 20 MINUTE MARK NOTIFICATION.

 

23:49 Hours -- PAR BEGUN

23:51 Hours -- PAR COMPLETE, ALL ACCOUNTED FOR

 

23:53 Hours -- OPERATIONS REQUESTS ADDITIONAL MANPOWER FOR OVERHAUL

23:55 Hours -- E3 REASSIGNED TO OVERHAUL, 254 CREW ASSIGNED TO RIC

 

23:59 Hours -- COMMAND REPORTING RG&E HAS SECURED GAS & ELECTRIC TO THE BUILDING

 

00:02 Hours -- TOWN BUILDING REP ON SCENE & REQUESTS EMERGENCY ENCLOSURES

 

00:05 Hours -- COMMAND STATUS UPDATE - COMPANIES ARE CONTINUING OVERHAUL, PULLING CEILINGS. 2C39 IS ASSIGNED AS THE REHAB MANAGER.  COMPANIES ARE BEING ROTATED THROUGH REHAB & OVERHAUL.

 

00:08 Hours-- SCOTT FROM COUNTY HEALTH DEPT CONTACTS DISPATCH, GIVEN 4C15 CONTACT INFO & ADVISED OF SITUATION.

 

00:11 Hours -- ROB FROM EMERGENCY ENCLOSURES CONTACTED, 30 MINUTE ETA

 

00:32 Hours -- OPERATIONS REQUESTS CREW TO ASSIST WITH BEGINNING TO TAKE DOWN FANS

 

00:34 Hours -- COMMAND RELEASING B2, E3, 2912, 2C39 & 254

 

00:55 Hours -- 4C15 IN SERVICE, 4C25 ASSUMING COMMAND

 

01:20 Hours -- COMMAND REPORTS UNITS ARE PICKING UP. RELEASING 252, 4310 & GATES AMBULANCE CREWS

 

01:25 Hours -- EMERGENCY ENCLOSURES ON SCENE

 

01:36 Hours-- 4C25 TERMINATES COMMAND & IS IN SERVICE. UNITS WILL CALL BACK AS THEY ARE READY.

 

01:39 Hours -- BUILDING TURNED OVER TO EMERGENCY ENCLOSURES & A PROPERTY REPRESENTATIVE. ASSIGNMENT IS IN SERVICE.

 

MCFB RESPONDED AS INVESTIGATION UNIT.  FIRE ON THE BACK SIDE OF THE EXTERIOR LIGHT ON THE INTERIOR OF THE COCK LOFT STARTED BURNING A WOOD STUD THAT EXTENDED HEAVILY TO THE INSULATION THROUGHOUT THE PLENUM AREA OF ENTIRE BUILDING.  FD PULLED ALL DROP CEILING AND WET DOWN ALL CEILING AREA.  HEAVY WATER AND SMOKE DAMAGE TO INTERIOR OF BUILDING

Comments

What Worked

Checking for extension

Vertical ventilation

Calling for the 2nd alarm

Luck

 

Lessons Learned

Verbalize sides of building

Maintaining crew integrity

Slowing down when talking into portable radio while giving a report

 

Incident went from a "slam dunk to an OH CRAP"

Never let down your guard...stay persistant in checking for extension if smoke conditions dont improve.  With that persistants we were able to discover multiple pockets of fire in the insulation above the ceiling tiles.  It wasnt a large volume of fire, but many pockets of small to moderate fire.  This turned out to be a labor intensive fire and the 2nd alarm definetly helped.

 

Taco Bell

4522 - Base Unit 4512 - Water Supply (out of Picture 4530 - Aerial to roof for ventilation 4310 - C/D corner if needed

Want to try out the mapping tool?